Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Med ; 11(3)2022 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-35160333

RESUMO

Coil embolization has become a well-established option for the treatment of intracranial aneurysms. Yet, wide-neck bifurcation aneurysms (WNBAs) remain a challenge. The pCONUS is the first generation of a stent-like implant for the bridging of WNBAs to enable coiling. The pToWin study was a prospective, single-arm, multicenter study conducted to analyze the safety and efficacy of the pCONUS in the treatment of WNBAs. The primary effectiveness endpoint was the rate of adequate occlusion of the aneurysm at 3-6 and 7-12 months. The primary safety endpoint was the occurrence of major ipsilateral stroke or neurological death during the follow-up. A total of 115 patients were included. Aneurysm locations were the middle cerebral artery in 52 (45.2%), the anterior communicating artery in 35 (30.4%), the basilar artery in 23 (20%), the internal carotid artery terminus in three (2.6%), and the pericallosal artery in two (1.7%) patients. Treatment was successfully performed in all but one patient. The morbi-mortality rate was 1.9% and 2.3% at 3-6 and 7-12 months, respectively. Of the aneurysms, 75.0% and 65.6% showed adequate occlusion at 3-6 and 7-12 months, respectively. pCONUS offers a safe and reasonably effective treatment of WNBAs, demonstrated by acceptable adequate aneurysm occlusion and low rates of adverse neurologic events.

2.
J Neurointerv Surg ; 9(1): 70-76, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27439887

RESUMO

BACKGROUND: Experience with the endovascular treatment of cerebral aneurysms using the p64 Flow Modulation Device is still limited. This study discusses the results and complications of this new flow diverter device. METHODS: 40 patients (30 women, 10 men) with 50 cerebral aneurysms treated in six Italian neurointerventional centers with the p64 Flow Modulation Device between April 2013 and September 2015 were retrospectively reviewed. RESULTS: Complete occlusion was obtained in 44/50 aneurysms (88%) and partial occlusion in 3 (6%). In the other three aneurysms (6%), two cases of asymptomatic in-stent thrombosis and one intraprocedural occlusion of the parent vessel occurred. Technical complications were observed in eight procedures (16%). Permanent morbidity due to acute in-stent thrombosis and consequent ischemic stroke occurred in one patient (2.5%). No delayed aneurysm rupture, subarachnoid or intraparenchymal hemorrhage, or ischemic complications occurred and there were no deaths. CONCLUSIONS: Endovascular treatment with the p64 Flow Modulation Device is a safe treatment for unruptured cerebral aneurysms, resulting in a high rate of occlusion. As with other flow diverter devices, we recommend this treatment mainly for large-necked aneurysms of the internal carotid artery siphon. However, endovascular treatment with the p64 device should also be encouraged in difficult cases such as aneurysms of the posterior circulation and beyond the circle of Willis.


Assuntos
Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Adulto , Idoso , Artéria Carótida Interna/diagnóstico por imagem , Angiografia Cerebral/métodos , Embolização Terapêutica/instrumentação , Embolização Terapêutica/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Stents , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/terapia , Fatores de Tempo , Resultado do Tratamento
3.
J Neurointerv Surg ; 8(3): 287-94, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25603808

RESUMO

PURPOSE: Experience with the endovascular treatment of middle cerebral artery (MCA) aneurysms by flow diverter devices (FDD) is still limited. This study examines the results and complications of FDD for small aneurysms at this location. METHODS: From February 2010 to December 2013, 14 patients (10 women; mean age 59 years) with 15 small MCA aneurysms were treated with FDD. All procedures were performed with the Pipeline embolization device (PED). RESULTS: Complete occlusion was obtained in 12/15 aneurysms (80%) and partial occlusion in 3 (20%). Among 13 aneurysms with a side branch, this was patent at the angiographic control in 4 cases, showed decreased filling in 6, and was occluded in 3 (with neurological deficits in 2). All PEDs were patent at follow-up. Post-procedural ischemic complications occurred in 4 (27%) procedures with permanent neurological deficit (modified Rankin score 2) in 3 (21%). No early or delayed aneurysm rupture, no subarachnoid or intraparenchymal hemorrhage and no deaths occurred. CONCLUSIONS: Endovascular treatment with FDD is a relatively safe treatment for small MCA aneurysms resulting in a high occlusion rate. The findings of this study suggest that complete occlusion after endovascular treatment with FDD can be delayed (>6 months). Ischemic complications may occur as early or delayed, particularly at clopidogrel interruption.


Assuntos
Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/métodos , Aneurisma Intracraniano/cirurgia , Adulto , Idoso , Angiografia Cerebral , Feminino , Seguimentos , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
4.
Neuroradiology ; 54(10): 1145-52, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22569955

RESUMO

INTRODUCTION: We report the experiences of 25 Italian centers, analyzing intra- and periprocedural complications of endovascular treatment of intracranial aneurysms using Silk (Balt Extrusion, Montmorency, France) and pipeline embolization devices (EV3 Inc, Irvine California). METHODS: Two hundred seventy-three patients with 295 cerebral aneurysms, enrolled in 25 centers in Italy and treated with the new flow-diverter devices, were evaluated; 142 patients were treated with Silk and 130 with pipeline (in one case, both devices were used). In 14 (5.2 %) cases devices were used with coils. Aneurysm size was >15 mm in 46.9 %, 5-15 mm in 42.2 %, and <5 mm in 10.8 %. Aneurysm locations were supraclinoid internal carotid artery (ICA) in 163 cases (55.2 %), cavernous ICA in 76 (25.7 %), middle cerebral artery in 11 (3.7 %), PCoA in 6 (2 %), and ACoA in 2 (0.7 %); the vertebrobasilar system accounted for 32 cases (10.8 %) and PCA in 5 (1.7 %). RESULTS: Technical adverse events occurred with 59 patients (21.6 %); 5 patients died after ischemic events, 10 to hemorrhagic complications, and 1 from external ventricular drain positioning. At 1 month, morbidity and mortality rates were 3.7 % and 5.9 %, respectively CONCLUSION: Our retrospective study confirms that morbidity and mortality rates in treatment with FDD of unruptured wide-neck or untreatable cerebral aneurysms do not differ from those reported in the largest series.


Assuntos
Prótese Vascular/estatística & dados numéricos , Aneurisma Intracraniano/mortalidade , Aneurisma Intracraniano/cirurgia , Complicações Pós-Operatórias/mortalidade , Stents/estatística & dados numéricos , Idoso , Aneurisma Roto/mortalidade , Aneurisma Roto/cirurgia , Comorbidade , Feminino , Humanos , Incidência , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Análise de Sobrevida , Taxa de Sobrevida , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...